Skip to content
English
  • There are no suggestions because the search field is empty.

UDI Adaptors Design

UDI adaptor design for Illumina sequencing

For 8 and 16 sample kits, the following 16 UDI pairs are available for purchase. For the full list UDIs for 96 sample kit, please see here.

CS Genetics’ UDI pairs are designed as shown below:

P7 Adaptor (5'-3')

CAAGCAGAAGACGGCATACGAGAT [i7] GTGACTGGAGTTCAGACGTGTGCTCTTCCGATC

 P5 Adaptor (5'-3')

AATGATACGGCGACCACCGAGATCTACAC [i5] ACACTCTTTCCCTACACGACGCTCTTCCGATCT

 

Please use the following sequences in your Sample Sheets. The reverse complement orientation of i5 is required for certain Illumina instruments. Please consult your instrument guide.

Index Pair Name Index Sequence 1 (i7) Index Sequence 2 (i5) in Forward Orientation (NextSeq2000 Orientation)
UDI 1 (I1) GAACTGAGCG TCGTGGAGCG
UDI 2 (I2) AGGTCAGATA CTACAAGATA
UDI 3 (I3) CGTCTCATAT TATAGTAGCT
UDI 4 (I4) ATTCCATAAG TGCCTGGTGG
UDI 5 (I5) GACGAGATTA ACATTATCCT
UDI 6 (I6) AACATCGCGC GTCCACTTGT
UDI 7 (I7) CTAGTGCTCT TGGAACAGTA
UDI 8 (I8) GATCAAGGCA CCTTGTTAAT
UDI 9 (I9) GACTGAGTAG GTTGATAGTG
UDI 10 (I10) AGTCAGACGA ACCAGCGACA
UDI 11 (I11) CCGTATGTTC CATACACTGT
UDI 12 (I12) GAGTCATAGG GTGTGGCGCT
UDI 13 (I13) CTTGCCATTA ATCACGAAGG
UDI 14 (I14) GAAGCGGCAC CGGCTCTACT
UDI 15 (I15) TCCATTGCCG GAATGCACGA
UDI 16 (I16) CGGTTACGGC AAGACTATAG